3670 - NovaSafety centrifuge (Made in Germany) Table centrifuge with angular rotor can be used for the determination offat content according to Dr. N. Gerber’s method as well asfor the determination of the solubility of powdered milk with special Solubilityglasses (ArtNr. 3637)Properties:Automatic interlocking lidAutomatic brake (braking time < 8 s)Centrifugation timer (digital)Heater, thermostatic set point at 65°CCapacity: max. 8 butyrometerTechnical specifications:RCF: 350 g +/- 50 gspeed: 1350 rpmEffective radius:170 mmWeight:13 kgDimensions (l x w x h): 470 x 380 x 230 mm electrical supply : 230V/50..60 Hz
3680 - Multipurpose centrifuge SuperVario-N (Made in Germany) Centrifuge for the determination of fat according to Gerber, Röse-Gottlieb, Babcock and for the determination of the solubility of milk powder (ADPI) characteristics: stainless steel case Programmable speed from 600 rpm to 1130 rpm in steps of 10 rpm (corresponds to a g-force of 77 to 372 g, depending on the rotor) Programmable heating up to 68 ° C in 1 ° steps Centrifugation time programmable from 1-99 minutes Automatic safety lid locking Automatic unbalance shutdown Automatic brake Technical specifications: Connection value: 230 V / 50 .. 60 Hz / 1200 VA Empty weight: 26 kg Total height with lid: 460 mm Ø outside: 670 mm Filling height: 370 mm Speed range: 600 to 1130 rpm Temperature range: room temperature to 68 ° C
3680-L - Safety centrifuge for fat content determination acc. to Roese-Gottlieb's method (Made in Germany) complete with Head B and inspection book This centrifuge consists of the same stainless steel centrifuge as the centrifuge "Super Vario N". The same HEAD is also used. important: This Centrifuge is only for Roese-Gottlieb. 8 Mojonnier tubes can be centrifuged at the same time.Speed: 600 U/min. The differences to the well-known centrifuge consist in the following point: • The centrifuge is equipped with a special explosion-proof motor. • The electronic control unit of this centrifuge is not built in, but connected to the centrifuge with an approx. 3 m long shielding cable. • This control unit must be installed in an adjoining room of the explosion-proof laboratory room. • The acrylic glass cover is also provided with a conductive coating (protective coating). This prevents the static charges. • For safety reasons, no lid lock must be attached to this centrifuge. • The centrifuge has no heating Dimensions: W x D x H: (435x280x160) mm
3670-110 - NovaSafety centrifuge 110 V (Made in Germany) Table centrifuge with angular rotor can be used for the determination of fat content according to Dr. N. Gerber’s method as well as for the determination of the solubility of powdered milk with special Solubilityglasses (ArtNr. 3637) Properties: Automatic interlocking lid Automatic brake (braking time < 8 s) Centrifugation timer (digital) Heater, thermostatic set point at 65°C Capacity: max. 8 butyrometer Technical specifications: RCF:350 g +/- 50 gspeed: 1350rpm Effective radius:170 mm Weight:13 kg Dimensions (l x w x h): 470 x 380 x 230 mm electrical supply : 110 V